On Thu, 4 Mar 2021 12:09:21 -0000
rmluglist2--- via Hampshire <hampshire@???> wrote:
Hello rmluglist2---,
>a) the length of the cable or
Unlikely; Cable runs of up to 100m should be okay. Difficult to reach
in a domestic setting.
>b) the quality of the cable or
More likely.
You also mentioned (lack of) cable movement. Don't be so sure -
expansion/contraction as temperature changes may play a part.
To say nothing of routing. Esp. if the cable ever goes under floor or
via the loft. Then rodents and all sorts of other critters might enter
the mix.
--
Regards _
/ ) "The blindingly obvious is
/ _)rad never immediately apparent"